2003 Coachmen Cheyenne & 2003 Coachmen Leprechaun + 2 more recall: electrical system
⚠️ What's wrong
On certain class c mini-motor homes, the generator exhaust pipe may have been assembled and installed incorrectly resulting in insufficient clearance to or contact with the chassis fuel fill tube.
💥 The risk
When operating, the generator's exhaust pipe may reach temperatures that could potentially melt and/or ignite the fuel fill tube. Should this occur, the potential exists for a fire.
🔧 The fix
Dealers will disassemble a portion of the generator exhaust pipe assembly, turning one of the bent components around 180 degrees, reassembling the exhaust pipe and measuring to ensure a minimum of 3" air gap with surrounding components. Owner notification began march 24, 2003. Owners who take their vehicles to an authorized dealer on an agreed upon service date and do not receive the free remedy within a reasonable time should contact coachmen at 1-800-453-6064.
- NHTSA campaign
- 03V081000
- Manufacturer
- COACHMEN RV COMPANY
- Vehicles affected
- 109
- Component
- ELECTRICAL SYSTEM:ALTERNATOR/GENERATOR/REGULATOR
- Owner phone
- 1-800-453-6064
- NHTSA hotline
- 1-888-327-4236
- Owner letters mailed
- Mar 24, 2003
- Built
- Dec 13, 2002 – Feb 26, 2003
- Recall started by
- MFR
- Notes
- Customers CAN also contact the national highway traffic safety administration's auto safety hotline at 1-888-DASH-2-DOT (1-888-327-4236).